Industries
Coking
When converting heavy hydrocarbon streams to lighter industrial products, the thermal cracking process calls for the frequent operation of the isolation valve system during the coke drum switching operation.

MOGAS’ floating ball design provides trouble-free operation in heavy coking applications. In addition, our unique design requires significantly less steam during purging operations than traditional trunnion designs, saving operators thousand of dollars in energy costs.

In an effort to continuously improve our design, MOGAS has compiled field data to determine the precise amount of service duty to be applied to actuator and valve stem sizing to prevent failures caused by increased torque due to coke buildup.

Operating Conditions:
  • High Temperatures: 500 oF – 900 oF
  • Coking Service
  • HP Steam Blowdown
  • High Pressure Water Service
  • High Cycles
  • Temperature Cycling
  • Erosive Conditions